24x7 Hotspot Detection
-
Enhances Safety
-
Saves Costs
-
Increases Efficiency

Build resilience into power distribution systems
Exertherm’s Bus Duct Monitoring Solution matches the modularity of bus duct, is quick and easy to install, and just as versatile.
It gives users a call-to-action on a specific joint which is potentially faulty and needs attention before a more serious problem occurs.
Continuous monitoring provides a 24x7 early warning system to detect critical temperature rise and reduce the risk of power loss.
Features
Simple installation
- Works straight out of the box
- Attaches quickly and easily
- Sensors fit directly to joints
- No complex commissioning
Flexible solution
- Modular build
- Install at the same time as bus duct
- Fits all complex bus duct systems
- Maintenance free
Data integration
- Provides 24x7 temperature and alarm data
- Modbus 485 data taken direct to EPMS/BMS
Benefits
Save money
- Lower CAPEX – eliminates the need for thermography at install
- Lower OPEX – eliminates continuous maintenance and periodic inspection
- Avoid cost of unplanned outages
Enhance safety
- Minimize personnel interaction with faulty, compromised or potentially dangerous electrical assets
Increase efficiency
- Protect against unplanned downtime and revenue loss by monitoring 24x7
Identify potentially faulty joints
- 1Modbus datacard connectivity
- 2Sensors alert operators
- 3Simple C-clip attachment
- 4Sensors align with joints
- 58 sensors over 24m lengths

Sensor cables ‘daisy chain’ together with simple modbus datacard connectivity

Sensors alert operators to a specific location when a change in temperature occurs

Simple C-clip attaches cables to bus duct joints

Sensors correspond to bus duct sections and align with joints

Sensor cable supplied in 24m lengths comprising 8 thermal sensors


Sensor cables ‘daisy chain’ together with simple modbus datacard connectivity

Sensors alert operators to a specific location when a change in temperature occurs

Simple C-clip attaches cables to bus duct joints

Sensors correspond to bus duct sectionsand align with joints

Sensor cable supplied in 24m lengths comprising8 thermal sensors


Sensor cables ‘daisy chain’ together with simple modbus datacard connectivity

Sensors alert operators to a specific location when a change in temperature occurs

Simple C-clip attaches cables to bus duct joints

Sensors correspond to bus duct sections and align with joints

Sensor cable supplied in 24m lengths comprising 8 thermal sensors


Sensor cables ‘daisy chain’ together with simple modbus datacard connectivity

Sensors alert operators to a specific location when a change in temperature occurs

Simple C-clip attaches cables to bus duct joints

Sensors correspond to bus duct sections and align with joints

Sensor cable supplied in 24m lengths comprising 8 thermal sensors


Sensor cables ‘daisy chain’ together with simple modbus datacard connectivity

Sensors alert operators to a specific location when a change in temperature occurs

Simple C-clip attaches cables to bus duct joints

Sensors correspond to bus duct sectionsand align with joints

Cable supplied in 24m lengths comprising 8 thermal sensors

Why choose Exertherm?
Exertherm has a history of technological innovation spanning over 30 years. As a world leader in thermal monitoring of electrical and mechanical infrastructure, we have developed a suite of solutions to help build resilience into power distribution networks.
Here's why you can trust Exertherm products:
-
Global OEM Approval
-
24x7 Thermal Monitoring
-
Zero Maintenance
-
Lifetime Guarantee
-
Simple Installation
Bus Duct Monitoring Solution - how it works

24x7 Hotspot Detection Solutions
The ease of installation and modularity of the overhead bus duct allows fast setup, quick repairs, and easy upgrades.
With all electrical assets, joints are typically the weak spots where faults occur, resulting in outages.
A compromised joint can only be identified by the excess heat it generates. Hotspots that are not identified and corrected can lead to power failures or worse - fire.
Discover how to build resilience into power distribution with 24x7 hotspot detection for bus duct.